List of parameters
Parameters
1-551
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
[25] = PZD 26
[26] = PZD 27
[27] = PZD 28
[28] = PZD 29
[29] = PZD 30
[30] = PZD 31
[31] = PZD 32
Note:
IF1: Interface 1
Value range:
0 - 125: Bus address of the sender
255: Not occupied
Description:
Displays the PZD byte offset in the PROFIdrive receive telegram (master output).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
Note:
IF1: Interface 1
Value range:
0 - 242: Byte offset
255: Not occupied
Description:
Displays the PZD byte offset in the PROFIdrive receive telegram (master output).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
r2075[0...4]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
A_INF, B_INF,
CU_CX32, CU_S,
S_INF, TB30,
TM15DI_DO, TM31
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2075[0...15]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
SERVO, TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-