![Siemens SINAMICS S Series List Manual Download Page 260](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427260.webp)
Parameters
List of parameters
1-260
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Re bit 12:
The feedback signal of a line contactor (auxiliary contact) can be interconnected via BI: p0860.
Description:
Displays the status word of the infeed sequence control.
Note:
Re bit 0, 1, 2, 4, 6, 9:
For PROFIdrive, these signals are used for status word 1.
Description:
Displays the status word of the sequence control.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready to power up
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
04
No OFF2 active
OFF2 inactive
OFF2 active
-
06
Power-on inhibit
Yes
No
-
09
Control requested
Yes
No
-
11
Pre-charging compl
Yes
No
-
12
Line contactor closed
Yes
No
8934
r0899.0...12
CO/BO: Status word sequence control infeed / ZSW seq_ctrl INF
B_INF
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
8726
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready to power up
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
04
No OFF2 active
OFF2 inactive
OFF2 active
-
06
Power-on inhibit
Yes
No
-
09
Control requested
Yes
No
-
11
Pre-charging compl
Yes
No
-
12
Line contactor closed
Yes
No
-
r0899.0...15
CO/BO: Status word sequence control / ZSW seq_ctrl
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2503
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready to power up
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
03
Jog active
Yes
No
-
04
No coasting active
OFF2 inactive
OFF2 active
-
05
No Quick Stop active
OFF3 inactive
OFF3 active
-
06
Power-on inhibit active
Yes
No
-
07
Drive ready
Yes
No
-
08
Controller enable
Yes
No
-
09
Control requested
Yes
No
-
11
Pulses enabled
Yes
No
-
12
Holding brake open
Yes
No
-
13
Command close holding brake
Yes
No
-
14
Pulse enable from the brake control
Yes
No
-
15
Setpoint enable from the brake control
Yes
No
-