Parameters
List of parameters
1-484
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the corrective value of the kT adaptation of the motor model for a permanent-magnet synchronous motor
(PEM).
Dependency:
Refer to: p1780, p1795
Description:
Displays the corrective value of the kT adaptation of the motor model for a permanent-magnet synchronous motor
(PEM).
Dependency:
Refer to: p1780, p1795
Description:
Displays the corrective value of the kT adaptation of the motor model for a permanent-magnet synchronous motor
(PEM).
Description:
Sets the drive converter switching frequency.
This parameter is preset to the rated converter value when the drive is first commissioned.
Dependency:
The pulse frequency can, depending on the current controller sampling time (p0115[0]) assume the following val-
ues.
a) p1800 = 1000 / (p0115[0] * n) with n = 2, 3, 4
b) p1800 = 1000 * n / p0115[0] with n = 1, 2, 3, 4, ...
Example:
p0115[0] = 125 µs --> p1800 = 2, 2.6, 4 kHz (from equation a)
p0115[0] = 125 µs --> p1800 = 8, 16 kHz (from equation b)
Possible setting values can be taken from r0114 (if p0009 = p0010 = 0).
Refer to: r0110, r0111, p0112, p0113, r0114, p0115, p0230, p1817
r1797
Motor model kT adaptation corrective value / MotMod kT corr
SERVO (Exp M_ctrl)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Nm/A]
- [Nm/A]
- [Nm/A]
r1797
Motor model kT adaptation corrective value / MotMod kT corr
SERVO (Exp M_ctrl,
Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [N/Arms]
- [N/Arms]
- [N/Arms]
r1797[0...n]
Motor model kT adaptation corrective value / MotMod kT corr
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
6731
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Nm/A]
- [Nm/A]
- [Nm/A]
p1800[0...n]
Pulse frequency / Pulse frequency
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Modulation
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1.000 [kHz]
16.000 [kHz]
4.000 [kHz]