Parameters
List of parameters
1-168
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
For p0393 = 100 % or p1402 bit 2 = 0, the current controller adaptation is disabled and p1715 is effective over the
entire range.
Description:
Sets the starting point of the current-dependent current controller adaptation where the adapted current controller
gain p1715 * p0393 is effective.
Dependency:
Refer to: p0391, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Description:
Sets the factor for the current controller P gain in the adaptation range (current greater than p0392). The value is
referred to p1715.
Dependency:
Refer to: p0391, p0392, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note:
For p0393 = 100 % or p1402 bit 2 = 0, the current controller adaptation is disabled and p1715 is effective over the
entire range.
Description:
Sets the factor for the current controller P gain in the adaptation range (e.g. r0078 > p0392, if p0392 > p0391). The
value is referred to p1715.
Dependency:
Refer to: p0391, p0392, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note:
For p0393 = 100 % or p1402 bit 2 = 0, the current controller adaptation is disabled and p1715 is effective over the
entire range.
p0392[0...n]
Current controller adaptation, starting point KP adapted / I_adapt pt KP adap
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6714
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p0393[0...n]
Current controller adaptation p gain adaptation / I_adapt Kp adapt
SERVO
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
5714
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [%]
1000.00 [%]
100.00 [%]
p0393[0...n]
Current controller adaptation P gain scaling / I_adapt Kp scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6714
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [%]
1000.00 [%]
100.00 [%]