List of parameters
Parameters
1-393
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the denominator damping for velocity setpoint filter 2 (PT2, general filter).
Dependency:
Refer to: p1414, p1421
Note:
This parameter is only effective if the velocity filter is parameterized as a PT2 low pass or as general filter.
Description:
Sets the numerator natural frequency for speed setpoint filter 2 (general filter).
Dependency:
Refer to: p1414, p1421
Note:
This parameter is only effective if the speed filter is set as a general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
Description:
Sets the numerator natural frequency for velocity setpoint filter 2 (general filter).
Dependency:
Refer to: p1414, p1421
Note:
This parameter is only effective if the velocity filter is set as a general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
Description:
Sets the numerator damping for speed setpoint filter 2 (general filter).
Dependency:
Refer to: p1414, p1421
Note:
This parameter is only effective if the speed filter is set as a general filter.
p1424[0...n]
Velocity setpoint filter 2 denominator damping / v_set_filt 2 D_d
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.001 10.000
0.700
p1425[0...n]
Speed setpoint filter 2 numerator natural frequency / n_set_filt 2 fn_n
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1425[0...n]
Velocity setpoint filter 2 numerator natural frequency / v_set_filt 2 fn_n
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1426[0...n]
Speed setpoint filter 2 numerator damping / n_set_filt 2 D_n
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.700