List of parameters
Parameters
1-389
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the denominator natural frequency for velocity setpoint filter 1 (PT2, general filter).
Dependency:
Refer to: p1414, p1415
Note:
This parameter is only effective if the velocity filter is parameterized as a PT2 low pass or as general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
Description:
Sets the denominator natural frequency for the speed setpoint filter 1 (PT2) of the incremental encoder emulation.
Dependency:
Refer to: p1414
Note:
This parameter is only effective if the speed setpoint filter in p1414 is activated.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
Description:
Sets the denominator damping for the speed setpoint filter 1 (PT2, general filter).
Dependency:
Refer to: p1414, p1415
Note:
This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general filter.
Description:
Sets the denominator damping for the velocity setpoint filter 1 (PT2, general filter).
Dependency:
Refer to: p1414, p1415
Note:
This parameter is only effective if the velocity filter is parameterized as a PT2 low pass or as general filter.
p1417[0...n]
Velocity setpoint filter 1 denominator natural frequency / v_set_filt 1 fn_d
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1417[0...n]
Speed setpoint filter 1 denominator natural frequency / n_set_filt 1 fn_d
TM41
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
9674
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1418[0...n]
Speed setpoint filter 1 denominator damping / n_set_filt 1 D_d
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.001 10.000
0.700
p1418[0...n]
Velocity setpoint filter 1 denominator damping / v_set_filt 1 D_d
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.001 10.000
0.700