![Siemens SINAMICS S Series List Manual Download Page 294](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427294.webp)
Parameters
List of parameters
1-294
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets a value for the fixed speed / velocity setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets a value for the fixed speed / velocity setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets a value for the fixed speed / velocity setpoint 11.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets a value for the fixed speed / velocity setpoint 11.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3010
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-210000.000 [RPM]
210000.000 [RPM]
0.000 [RPM]
p1010[0...n]
CO: Fixed velocity setpoint 10 / n_set_fixed 10
SERVO (Extended
setp, Lin)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3010
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3010
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-210000.000 [RPM]
210000.000 [RPM]
0.000 [RPM]
p1011[0...n]
CO: Fixed velocity setpoint 11 / n_set_fixed 11
SERVO (Extended
setp, Lin)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3010
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]