Parameters
List of parameters
1-384
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the status word of the speed controller.
Note:
Re bit 04:
The following conditions must be fulfilled to set to 1:
- CI: p1190 and CI: p1191 must be interconnected with a signal source that is not equal to zero.
- it is not permissible that OFF1, OFF3 or STOP2 are active.
- it is not permissible that the motor data identification is active.
- it is not permissible that the master control is active.
The following conditions can mean that the DSC function is not active in spite of the fact that the bit is set:
- clock-cycle synchronous operation is not selected (r2054 not equal to 4).
- the PROFIBUS is not clock-cycle synchronous (r2064[0] not equal to 1).
- DSC is not switched-in on the control side; this means that KPC = 0 is transferred as value at CI: p1191.
Description:
Displays the status word of the velocity controller.
Note:
Re bit 04:
The following conditions must be fulfilled to set to 1:
- CI: p1190 and CI: p1191 must be interconnected with a signal source that is not equal to zero.
r1407.0...13
CO/BO: Status word speed controller / ZSW n_ctrl
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2522
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
V/f control active
Yes
No
-
01
Sensorless operation active
Yes
No
-
02
Torque control active
Yes
No
-
04
Speed setpoint from DSC
Yes
No
2522
05
Speed controller I component frozen
Yes
No
-
06
Speed controller I component set
Yes
No
-
07
Torque limit reached
Yes
No
5610
08
Upper torque limit active
Yes
No
5610
09
Lower torque limit active
Yes
No
5610
11
Speed setpoint limited
Yes
No
-
13
Sensorless operation due to a fault
Yes
No
-
r1407.0...13
CO/BO: Status word, velocity controller / ZSW v_ctrl
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2522
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
V/f control active
Yes
No
-
01
Sensorless operation active
Yes
No
-
02
Force control active
Yes
No
-
04
Velocity setpoint from DSC
Yes
No
2522
05
Velocity controller I component frozen
Yes
No
-
06
Velocity controller I component set
Yes
No
-
07
Force limit reached
Yes
No
5610
08
Upper force limit active
Yes
No
5610
09
Lower force limit active
Yes
No
5610
11
Velocity setpoint limited
Yes
No
-
13
Sensorless operation due to a fault
Yes
No
-