List of parameters
Parameters
1-675
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the actual position for the following events:
- external block change via measuring probe (p2632 = 0, BI: p2661 = 0/1 signal).
- external block change via BI: p2633 (p2632 = 1, BI: p2633 = 0/1 signal).
- activate traversing task (BI: p2631 = 0/1 signal).
Dependency:
Refer to: p2631, p2632, p2633, p2661
Description:
Displays the clearance determined between the reference cam and zero mark in the search for reference.
Description:
Displays the currently effective velocity override.
Dependency:
Refer to: p2571, p2646
Note:
The effective override can differ from the specified override due to limits (e.g. p2571, maximum velocity).
Description:
Displays the actual residual distance.
The remaining distance is the distance to still to be moved through up to the end of the current positioning task.
Dependency:
Refer to: r2665, r2671, r2678
r2678
CO: EPOS external block change / Ext BlckChg s_act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3615, 3616,
3620
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2680
CO: EPOS clearance, reference cam and zero mark / Clearance cam/ZM
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3612
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2681
CO: EPOS velocity override effective / v_over effective
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r2682
CO: EPOS residual distance to go / Residual distance
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3635
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]