List of parameters
Parameters
1-169
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the actual stator resistance (phase value).
The parameter is influenced by the temperature model and includes the temperature-independent cable resistance.
Dependency:
Refer to: p0350, p0352, p0620
Description:
Displays the actual rotor/secondary section resistance (phase value).
The parameter is influenced by the temperature model.
Dependency:
Refer to: p0354, p0620
Note:
This parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Selects the encoder from the list of encoder types supported.
Values:
0:
No encoder
1001: Resolver 1 speed
1002: Resolver 2 speed
1003: Resolver 3 speed
1004: Resolver 4 speed
2001: 2048, 1 Vpp, A/B C/D R
2002: 2048, 1 Vpp, A/B R
2003: 256, 1 Vpp, A/B R
2004: 400, 1 Vpp, A/B R
2005: 512, 1 Vpp, A/B R
2010: 18000, 1 Vpp, A/B R distance-coded
2051: 2048, 1 Vpp, A/B, EnDat, Multiturn 4096
2052: 32, 1 Vpp, A/B, EnDat, Multiturn 4096
2053: 512, 1 Vpp, A/B, EnDat, Multiturn 4096
2054: 16, 1 Vpp, A/B, EnDat, Multiturn 4096
2055: 2048, 1 Vpp, A/B, EnDat, Singleturn
2081: 2048, 1 Vpp, A/B, SSI, Singleturn
2082: 2048, 1 Vpp, A/B, SSI, Multiturn 4096
2083: 2048, 1 Vpp, A/B, SSI, Singleturn, error bit
2084: 2048, 1 Vpp, A/B, SSI, Multiturn 4096, error bit
2110: 4000 nm, 1 Vpp, A/B R distance-coded
2111: 20000 nm, 1 Vpp, A/B R distance-coded
r0395[0...n]
Stator resistance, actual / R_stator active
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6300, 6730,
6731
P-Group:
Motor
Units group:
16_1
Unit selection:
p0349
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
r0396[0...n]
Rotor resistance, actual / R_rotor active
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6730
P-Group:
Motor
Units group:
16_1
Unit selection:
p0349
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
p0400[0...n]
Enc type selection / Enc type selection
SERVO, VECTOR
Can be changed:
C2(1, 4)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
1580, 4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 10050
0