List of parameters
Parameters
1-435
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the scaling of the lower force limit or the regenerative force limit in p1523.
Dependency:
p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values. that are obtained as a result of the signal source and the scaling can cause the motor to accelerate
in an uncontrollable fashion.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Sets the signal source for the scaling of the lower torque limit in p1523.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values. that are obtained as a result of the signal source and the scaling can cause the motor to accelerate
in an uncontrollable fashion.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Sets the power limit when motoring.
Dependency:
Refer to: p0500, p1531
Note:
For VECTOR the following applies (p0107):
The power limit is limited to 300% rated motor power.
p1529[0...n]
CI: Force limit lower/regenerative scaling / F_max low/gen scal
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
1610, 3617,
5620, 5630
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1525[0]
p1529[0...n]
CI: Torque limit lower scaling / M_max lower scal
VECTOR (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
6630
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1525[0]
p1530[0...n]
Power limit motoring / P_max mot
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5640, 6640
P-Group:
Closed-loop control
Units group:
14_5
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [kW]
100000.00 [kW]
0.00 [kW]