Note:
Reference point setting is effective in the following operating states:
- in the basic state.
- for FIXED STOP with progress condition END (corresponds to the initial state).
- for traversing block interrupted via BI: p2640 = 0 signal (intermediate stop).
- for EPOS not enabled (BI: p2656 = 0 signal) and position actual value valid (BI: p2658 = 1 signal).
Description:
Sets the signal source to select referencing type.
1 signal: Flying referencing
0 signal: Search for reference
Dependency:
Refer to: p2595
Note:
Referencing is activated as follows:
- Select the referencing type (BI: p2597)
- Start referencing (BI: p2595 = 0/1 signal)
Description:
Sets the signal source for the reference point coordinate.
This value is used as reference for the following referencing operations:
- search for reference
- set reference point
- flying referencing
- absolute value adjustment
Index:
[0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency:
Refer to: p2502, p2507, p2595, p2596, p2597, p2599
Note:
When the function module "basic positioner" (r0108.4 = 1) is activated, the following applies:
Incremental measuring system:
After the reference point is reached, the drive accepts the actual axis position from the position received via the
connector input CI: p2598[0].
Absolute encoder:
When adjusting the encoder, the position received via the connector input is set as the actual axis position. The
position offset to the actual encoder value is displayed in p2525.
p2597
BI: EPOS referencing type selection / Ref_typ select
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3612, 3614,
3625
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2598[0...3]
CI: EPOS reference point coordinate, signal source / Ref_pt coord S_src
SERVO (EPOS, Pos
ctrl), VECTOR
(EPOS, Pos ctrl)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
3612
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
[0]
2599[0]
[1] 0
[2] 0
[3] 0