Parameters
List of parameters
1-386
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the status word of the closed-loop current control.
Description:
Sets the delay of the speed setpoint for the incremental encoder emulation.
Description:
Activates the speed setpoint filters 1 and 2.
Recommend.:
If only one filter is required, filter 1 should be activated and filter 2 deactivated, to avoid excessive processing time.
Dependency:
The speed setpoint filter is parameterized using p1415 ... p1420 and p1421 ... p1426.
Description:
Activates the velocity setpoint filters 1 and 2.
Recommend.:
If only one filter is required, filter 1 should be activated and filter 2 deactivated, to avoid excessive processing time.
r1408.0...12
CO/BO: Status word closed-loop current control / ZSW curr ctrl
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
2530
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Current ctrl act
Active
Not active
-
01
Id control, I-component limiting
Active
Not active
-
03
Voltage limiting
Active
Not active
-
10
Speed adaptation, limiting
Active
Not active
-
11
Speed adaptation, speed deviation
Out tolerance
In tolerance
6719
12
Motor stalled
Yes
No
6719,
8018
p1412[0...n]
Speed setpoint filter, dead time / n_set dead time
TM41
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
9674
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 [ms]
1.000 [ms]
0.000 [ms]
p1414[0...n]
Speed setpoint filter activation / n_set_filt active
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Activate filter 1
Yes
No
-
01
Activate filter 2
Yes
No
-
p1414[0...n]
Velocity setpoint filter activation / v_set_filt active
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0000
bin