List of parameters
Parameters
1-35
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the access level for reading and writing parameters using the Basic Operator Panel (BOP) and Advanced
Operator Panel (AOP).
Values:
0:
User-defined
1:
Standard
2:
Extended
3:
Expert
4:
Service
Note:
Access level 0 (user-defined):
Parameters from the user-defined list (p0013).
Access level 1 (standard):
Parameters for the simplest operator control possibility (e.g. p1120 = ramp-function generator, ramp-up time).
Access level 2 (extended):
Parameters to operate the basic functions of the drive unit.
Access level 3 (experts):
Expert know-how is required for these parameters (e.g. BICO parameterization).
Access level 4 (service):
For these parameters, it is necessary that authorized service personnel enter the appropriate password (p3950).
Description:
Sets the display filter for parameters for Basic Operator Panel (BOP) and Advanced Operator Panel (AOP).
Values:
0:
All parameters
1:
Displays, signals
2:
Power unit
3:
Motor
4:
Encoder/pos enc
5:
Technology/units
7:
Digital inputs/outputs commands sequence control
8:
Analog inputs/outputs
10:
Setpoint channel/ramp-fct generator
12:
Functions
13:
V/f control
14:
Control
15:
Data sets
17:
Basic positioner
18:
Gating unit
19:
Motor identification
20:
Communication
21:
Faults, alarms, monitoring functions
25:
Closed-loop position control
28:
Free function blocks
47:
Trace and function generator
50:
OA parameter
90:
Topology
p0003
BOP access level / BOP access level
CU_CX32, CU_S
Can be changed:
C1, U, T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 4
1
p0004
BOP display filter / BOP display filter
CU_CX32, CU_S
Can be changed:
C2(1), U, T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
ASM
Expert list:
1
Min Max
Factory
setting
0 99
0