![Siemens SINAMICS S Series List Manual Download Page 598](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427598.webp)
Parameters
List of parameters
1-598
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2185 > p2186
Refer to: p2182, p2186
Refer to: A07926
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2185 > p2186
Refer to: p2182, p2186
Refer to: A07926
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2186 < p2185
Refer to: p2182, p2185
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2186 < p2185
Refer to: p2182, p2185
Refer to: A07926
p2185[0...n]
Load monitoring torque threshold 1, upper / M_thresh 1 upper
SERVO (Extended
msg), VECTOR
(Extended msg)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm]
20000000.00 [Nm]
10000000.00 [Nm]
p2185[0...n]
Load monitoring force threshold 1, upper / M_thresh 1 upper
SERVO (Extended
msg, Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
8_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [N]
100000.00 [N]
100000.00 [N]
p2186[0...n]
Load monitoring torque threshold 1, lower / M_thresh 1 lower
SERVO (Extended
msg), VECTOR
(Extended msg)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
p2186[0...n]
Load monitoring force threshold 1, lower / M_thresh 1 lower
SERVO (Extended
msg, Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
8_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [N]
100000.00 [N]
0.00 [N]