List of parameters
Parameters
1-113
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
When the parameter is changed, all of the motor parameters and the control mode are pre-assigned according to
the selected application. The parameter has not influence when calculating the thermal overload.
p0205 can only be changed to the settings that are saved in the power unit EEPROM.
Its value is not reset when factory values are restored (see p0010 = 30, p0970).
Description:
Displays the rated power unit power for various load duty cycles.
Index:
[0] = Rating plate
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 continuous duty cycle
[4] = S6 load duty cycle
Dependency:
The value is displayed in [kW] or [hp].
Refer to: p0100, p0205
Description:
Displays the rated power unit power for various load duty cycles.
Index:
[0] = Rating plate
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 continuous duty cycle
[4] = S6 load duty cycle
Dependency:
Refer to: p0205
Description:
Displays the rated line supply voltage of the power unit.
r0208 = 400: 380 - 480 V +/-10 %
r0208 = 500: 500 - 600 V +/-10 %
r0208 = 690: 660 - 690 V +/-10 %
For the Basic Line Module (BLM) the following applies:
r0208 = 690 : 500 - 690 V +/-10 %
r0206[0...4]
Rated power unit power / PU P_rated
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Converter
Units group:
14_6
Unit selection:
p0100
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [kW]
- [kW]
- [kW]
r0207[0...4]
Rated power unit current / PU PI_rated
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8014
P-Group:
Converter
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0208
Rated power unit line supply voltage / PU V_rated
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Converter
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]