060 – Basic ramp-function
g
enera
to
r
- 3060 -
Function diagram
8
7
6
5
4
3
2
1
fp_3060_51_eng.vsd
DO: SERVO, VECTOR, VECTORGL, VECTORMV
SINAMICS
22.05.07 V02.05.00
Setpoint channel - Basic ramp-function generator
Ramp-down time
0.000...999 999.000 s
p1121[D] (10.000)
OFF3 ramp-down time
0.000...600.000 s
p1135[D] (0.000)
Ramp-up time
0.000...999 999.000 s
p1120[D] (10.000)
x
t
y
t
p1082
-p1082
x
p1082
-p1082
Tup
Tdn
Tup
Tdn
[3050.8]
y
0
0
0
0
[2634.4]
T
up
T
dn
r1119
RFG setpt at input
Threshold for
"Ramp-up/ramp-down active"
0.00...1000.00 RPM
p1148[D] (19.80)
0
1
x
y
[3050.5]
[3095.7]
n_max
p1082
From the setpoint limiting
Freeze ramp-function generator
[3080.1]
1
0
0
1
0
1
1
0
0
1
1
0
0 = Freeze ramp-function generator
r0898.5
1 = Enable speed setpoint
r0898.6
+
–
[2634.4]
1 = Enable ramp-function generator
r0898.4
Ramp-function generator, status bits
[3080.5]
0 = Internal fast stop
0 = Internal fast stop
Other status bits
Ramp-up active
Ramp-down active
n_set_4
[2501.7]
p1140
[2501.7]
p1141
[2501.7]
p1142
[3080.8]
Ramp flattening-off
p0115[3]
<101>
Refer to [1020.7]
1 = Internal RFG enable
[2634.4]
1 = Bypass ramp-function generator
r1198.15
[2505.7]
p1122
RFG setting value
(0)
p1144[C]
(0)
Accept RFG set val
p1143[C]
0
1
0
1
<1>
<1>
For SERVO and VECTOR, the following applies:
Inhibited during jogging.
<100> For SERVO, the following applies: Only if the function module
"Extended setpoint channel" is activated (r0108.8 = 1).
<101> To view the pre-assignment of the sampling times in p0115,
refer to p0112.
<100>
r1149
HLG acceleration