List of parameters
Parameters
1-215
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Description:
Defines the rated overtemperature of the stator winding referred to the ambient temperature.
Dependency:
For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Description:
Defines the rated overtemperature of the squirrel cage rotor referred to ambient temperature.
Dependency:
For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Description:
Displays the ambient temperature of the motor temperature model.
Description:
Displays the stator core temperature of the motor temperature model.
Description:
Displays the stator winding temperature of the motor temperature model.
p0627[0...n]
Motor overtemperature, stator winding / Mot T_over stator
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
8016
P-Group:
Motor
Units group:
21_2
Unit selection:
p0505
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
20 [K]
200 [K]
80 [K]
p0628[0...n]
Rotor winding overtemperature / Mot T_over rotor
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
8016
P-Group:
Motor
Units group:
21_2
Unit selection:
p0505
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
20 [K]
200 [K]
100 [K]
r0630[0...n]
Motor temperature model ambient temperature / MotTMod T_amb.
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
8016
P-Group:
Motor
Units group:
21_1
Unit selection:
p0505
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0631[0...n]
Motor temperature model, stator core temperature / MotTMod T_iron
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
8016
P-Group:
Motor
Units group:
21_1
Unit selection:
p0505
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0632[0...n]
Motor temperature model, stator winding temperature / MotTMod T_copper
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
8016
P-Group:
Motor
Units group:
21_1
Unit selection:
p0505
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]