List of parameters
Parameters
1-735
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
The values are integer multiples of the speed controller clock cycle (p0115[1]).
Description:
Sets the factor for the sub-sampling in the branch of filter 3.1 and 3.2 for APC (Advanced Positioning Control).
Note:
The values are integer multiples of the speed controller clock cycle (p0115[1]).
Description:
Sets the denominator natural frequency for filter 1.1 (PT2, general 2nd Order filter) for APC (Advanced Positioning
Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the denominator damping for filter 1.1 (PT2, general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the numerator natural frequency for filter 1.1 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the numerator damping for filter 1.1 (general 2nd Order filter) for APC (Advanced Positioning Control).
p3707[0...n]
APC sub-sampling, filter 3.x / APC sub-samp. 3.x
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
1 64
1
p3711[0...n]
APC filter 1.1 denominator natural frequency / APC Filt 1.1 fn_d
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p3712[0...n]
APC filter 1.1 denominator damping / APC Filt 1.1 D_d
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.050 10.000
0.700
p3713[0...n]
APC filter 1.1 numerator natural frequency / APC Filt 1 fn_n
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p3714[0...n]
APC filter 1.1 numerator damping / APC Filt 1.1 D_n
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.700