List of parameters
Parameters
1-327
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the configuration for the expanded ramp-function generator.
Caution:
Re bit 00 = 1:
If the ramp-up time is longer than the ramp-down time (p1120 > p1121), then there is an acceleration step at the
zero crossover. This can have a negative impact on the mechanical system.
Note:
Re bit 00 = 1:
When the direction change is changed there is no rounding-off before and after the zero crossover.
Description:
Sets the signal source for "setpoint 2 enable".
Description:
Sets the signal source for speed setpoint 1 of the speed controller.
Dependency:
The effectiveness of this setpoint depends on, e.g. STW1.4 and STW1.6.
Refer to: r0898, p1140, p1142, p1160, r1170
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Sets the signal source for the velocity setpoint 1 of the speed controller.
Dependency:
The effectiveness of this setpoint depends on, e.g. STW1.4 and STW1.6.
Refer to: r0898, p1140, p1142, p1160, r1170
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1151[0...n]
Ramp-function generator configuration / RFG config
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
3070
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Disable rounding-off at the zero cross-over
Yes
No
3070
p1152
BI: Setpoint 2 enable / Setp 2 enable
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
2711
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
899.15
p1155[0...n]
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
1550, 3080
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p1155[0...n]
CI: Velocity controller, velocity setpoint 1 / v_ctrl n_set 1
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
1550, 3080
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0