![Siemens SINAMICS S Series List Manual Download Page 412](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427412.webp)
Parameters
List of parameters
1-412
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Set the integral time for sensorless operation for the speed controller.
Description:
Set the integral time for sensorless operation for the velocity controller.
Description:
Sets the signal source to hold the integrator for the speed controller.
Description:
Sets the signal source to hold the integrator for the velocity controller.
Description:
Sets the signal source to set the integrator setting value (p1478).
Dependency:
Refer to: p1478, p1479
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1472[0...n]
Speed controller sensorless operation integral time / n_ctrl SLVC Tn
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.0 [ms]
100000.0 [ms]
20.0 [ms]
p1472[0...n]
Velocity controller sensorless operation integral time / v_ctrl SLVC Tn
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.0 [ms]
100000.0 [ms]
20.0 [ms]
p1476[0...n]
BI: Speed controller hold integrator / n_ctrl integ stop
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5040,
5042, 5210, 6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0
p1476[0...n]
BI: Velocity controller, hold integrator / v_ctrl integ stop
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5040,
5042, 5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0
p1477[0...n]
BI: Speed controller set integrator value / n_ctrl integ set
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5040,
5042, 5210, 6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0