Parameters
List of parameters
1-398
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Together with p1433 and p1434, the characteristics (in the time domain) of the P-controlled velocity control loop
can be emulated.
Refer to: p0115, p1433, p1434
Description:
Displays the speed setpoint at the output of the reference model.
Dependency:
For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
Description:
Displays the velocity setpoint at the output of the reference model.
Dependency:
For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
Description:
Sets the signal source for speed setpoint for the integral component of the speed controller.
Dependency:
The reference model is activated with p1400.3 = 1.
Refer to: p1400
Caution:
In should be ensured that a speed setpoint is selected as signal source that corresponds to the setpoint for the P
component of the speed controller.
Description:
Displays the speed setpoint after setpoint limiting for the P component of the speed controller.
For V/f operation, the value that is displayed is of no relevance.
Dependency:
Refer to: r1439
r1436
CO: Speed controller reference model speed setpoint output / RefMod n_set outp
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5030, 6031
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r1436
CO: Velocity controller, reference model velocity_setpoint output /
RefMod v_set outp
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5030, 6031
P-Group:
Closed-loop control
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
p1437[0...n]
CI: Speed controller, reference model I component input / n_ctrRefMod I_comp
VECTOR (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
6031
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1436[0]
r1438
CO: Speed controller, speed setpoint / n_ctrl n_set
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1550, 1590,
1700, 5030, 5040, 5042, 5210,
5300, 5620, 6031, 6040
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]