![Siemens SINAMICS S Series List Manual Download Page 594](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427594.webp)
Parameters
List of parameters
1-594
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the torque threshold value for the signal "Torque setpoint < torque threshold value 1" (BO: r2198.10).
Dependency:
Refer to: p2195, r2198
Description:
Sets the force threshold value for the signal "Torque setpoint < torque threshold value 1" (BO: r2198.10).
Dependency:
Refer to: p2195, r2198
Description:
Sets the speed threshold for the message "Motor locked" (BO: r2198.6).
Dependency:
Refer to: p0500, p2177, r2198
Description:
Sets the velocity threshold for the message "Motor locked" (BO: r2198.6).
Dependency:
Refer to: p0500, p2177, r2198
p2174[0...n]
Torque threshold value 1 / M_thresh val 1
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8012
P-Group:
Messages
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm]
20000000.00 [Nm]
5.13 [Nm]
p2174[0...n]
Force threshold value 1 / F_thresh val 1
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8012
P-Group:
Messages
Units group:
8_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [N]
20000000.00 [N]
1000.00 [N]
p2175[0...n]
Motor locked speed threshold / Mot lock n_thresh
SERVO, VECTOR
Can be changed:
U, T
Calculated:
CALC_MOD_LIM_REF
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8012
P-Group:
Messages
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
210000.00 [RPM]
120.00 [RPM]
p2175[0...n]
Motor locked, velocity threshold / Mot lock v_thresh
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_LIM_REF
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
8012
P-Group:
Messages
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [m/min]
1000.00 [m/min]
1.20 [m/min]