Parameters
List of parameters
1-532
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
The serial interface for the debug monitor is COM1 (X140) or COM2 (internal).
Value = 0: COM2 (internal)
Value = 1: COM1 (X140), PPI is de-activated
Description:
Sets the monitoring time to monitor the process data received via COMM BOARD. If no process data is received
within this time, an appropriate message is output.
Dependency:
Refer to: F08501
Note:
0: The monitoring is deactivated.
Description:
Sets the PROFIBUS Ident Number (PNO-ID).
SINAMICS can be operated with various identities on PROFIBUS. This allows the use of a PROFIBUS GSD that is
independent of the device (e.g. PROFIdrive VIK-NAMUR with Ident Number 3AA0 hex).
Values:
0:
SINAMICS S/G
1:
VIK-NAMUR
Note:
A new setting only becomes effective after POWER ON, reset or download.
p2039
Select debug monitor interface / Sel. debug monitor
CU_S
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p2040
COMM INT monitoring time / C INT t_monit
CU_CX32, CU_LINK
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
65535000 [ms]
20 [ms]
p2041[0...4]
PROFIBUS detail settings / PB detail
CU_S
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
p2042
PROFIBUS Ident Number / PB Ident No.
CU_S
Can be changed:
C1(1)
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0