Parameters
List of parameters
1-388
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the time constant for the speed setpoint filter 1 (PT1).
Dependency:
Refer to: p1414, p1415
Note:
For SERVO (p0107) the following applies:
This parameter is only effective if the speed filter is set as a PT1 low pass.
Description:
Sets the time constant for the velocity setpoint filter 1 (PT1).
Dependency:
Refer to: p1414, p1415
Note:
This parameter is only effective if the velocity filter is set as a PT1 low pass.
Description:
Sets the time constant for the speed setpoint filter 1 (PT1).
Note:
For SERVO (p0107) the following applies:
This parameter is only effective if the speed filter is set as a PT1 low pass.
Description:
Sets the denominator natural frequency for the speed setpoint filter 1 (PT2, general filter).
Dependency:
Refer to: p1414, p1415
Note:
This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 T
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1416[0...n]
Velocity setpoint filter 1 time constant / v_set_filt 1 T
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 T
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
6030
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1417[0...n]
Speed setpoint filter 1 denominator natural frequency / n_set_filt 1 fn_d
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]