List of parameters
Parameters
1-221
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Factor to evaluate the damping inductance quadrature to the rotor axis (q axis).
Dependency:
Refer to: p0359, r0381
Description:
Factor to evaluate the damping resistance in the direction of the rotor axis (d axis).
Dependency:
Refer to: p0354, r0374
Description:
Factor to evaluate the damping resistance quadrature to the rotor axis (q axis).
Dependency:
Refer to: p0355, r0375
Description:
Sets the digital input used for the function "central measuring probe evaluation".
p0680[0]: Digital input, measuring probe 1
p0680[1]: Digital input, measuring probe 2
p0680[2]: Digital input, measuring probe 3
p0680[3]: Digital input, measuring probe 4
p0680[4]: Digital input, measuring probe 5
p0680[5]: Digital input, measuring probe 6
Values:
0:
No meas probe
1:
DI/DO 9 (X122.8/X121.8)
2:
DI/DO 10 (X122.10/X121.10)
3:
DI/DO 11 (X122.11/X121.11)
4:
DI/DO 13 (X132.8)
5:
DI/DO 14 (X132.10)
6:
DI/DO 15 (X132.11)
p0658[0...n]
Motor damping inductance, q axis scaling / Mot L_damp q scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0659[0...n]
Motor damping resistance, d axis scaling / Mot R_damp d scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0660[0...n]
Motor damping resistance, q axis scaling / Mot R_damp q scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0680[0...5]
Central measuring probe, input terminal / Cen meas inp
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 6
0