List of parameters
Parameters
1-687
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Optimum load angle for synchronous motors with reluctance torque set from the motor identification (e.g. 1FE ...
motors).
This parameter has no significance for induction motors.
SERVO: The load angle is measured at 150% rated motor current.
Description:
Reluctance torque constant for synchronous motors with reluctance torque set from the motor identification (e.g.
1FE ... motors).
This parameter has no significance for induction motors.
Description:
Reluctance force constant for synchronous motors with reluctance force set from the motor identification (e.g. 1FE
... motors).
This parameter has no significance for induction motors.
Description:
Angular commutation offset determined from the motor identification.
p3027
Motor identification - optimum load angle / MotId phi_load opt
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
0.0 [°]
135.0 [°]
0.0 [°]
p3028
Motor identification - reluctance torque constant / MotId kT_reluct
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
-1000.00 [mH]
1000.00 [mH]
0.00 [mH]
p3028
Motor identification - reluctance force constant / MotId kT_reluct
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
-1000.00 [mH]
1000.00 [mH]
0.00 [mH]
p3030
Motor identification - angular commutation offset / MotId AngComOffset
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-180.00 [°]
180.00 [°]
0.00 [°]