![Siemens SINAMICS S Series List Manual Download Page 979](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427979.webp)
List of parameters
Parameters
1-979
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the limit values for the function "Safely-Limited Speed" (SLS).
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency:
Refer to: p9363, p9531
Refer to: C01714
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed
Description:
Sets the tolerance for the cross-check of the actual position between the two monitoring channels.
Dependency:
Refer to: p9542
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the tolerance for the cross-check of the actual position between the two monitoring channels.
Dependency:
Refer to: p9542
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
p9331[0...3]
SI motion SLS limit values (Motor Module) / SI Mtn SLS lim MM
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
1000000.00 [RPM]
2000.00 [RPM]
p9342
SI motion act val comparison tol (crosswise) (Motor Module) / SI Mtn act tol MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.0010 [mm]
360.0000 [mm]
0.1000 [mm]
p9342
SI motion act val comparison tol (crosswise) (Motor Module) / SI Mtn act tol MM
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.0010 [°]
360.0000 [°]
0.1000 [°]