![Siemens SINAMICS S Series List Manual Download Page 152](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427152.webp)
Parameters
List of parameters
1-152
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
p0340 = 5 only calculates the controller limits.
When existing the quick commissioning using p3900 > 0, p0340 is automatically set to 1.
At the end of the calculations, p0340 is automatically set to 0.
If the STARTER commissioning software (start-up tool) writes a 3 into p0340 when "downloading into the target
device", then this corresponds to a "complete calculation of the motor/control parameters without equivalent circuit
diagram data". The same calculations are carried out as for p0340 = 1, however, without the equivalent circuit dia-
gram parameters of the motor (p0340 = 2), the motor moment of inertia (p0341) and the motor weight (p0344).
For third-party linear synchronous motors (p0300 = 4) equivalent circuit diagram data are not calculated (p0340 =
2).
Description:
Sets the motor moment of inertia (without load).
Dependency:
This means that together with p0342, the rated starting time of the motor is calculated.
Refer to: p0342, r0345
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note:
The parameter is automatically preset for motors from the motor list (p0301).
SERVO:
p0341 * p0342 + p1498 influence the speed/torque pre-control in sensorless operation.
VECTOR:
The product p0341 * p0342 is taken into account when automatically calculating the speed controller (p0340 = 4).
Description:
Sets the high moments of inertia (without load).
Dependency:
This means that together with p0342, the rated starting time of the motor is calculated.
Refer to: p0342, r0345
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note:
The parameter is automatically preset for motors from the motor list (p0301).
SERVO:
p0341 * p0342 + p1498 influence the speed/torque pre-control in sensorless operation.
p0341[0...n]
Motor moment of inertia / Mot M_mom of inert
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
1700, 5042,
5210, 6030, 6031
P-Group:
Motor
Units group:
25_1
Unit selection:
p0100
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
p0341[0...n]
Motor weight / Mot weight
SERVO (Lin)
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
5042, 5210
P-Group:
Motor
Units group:
27_1
Unit selection:
p0100
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000000 [kg]
10000.000000 [kg]
0.000000 [kg]