![Siemens SINAMICS S Series List Manual Download Page 766](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427766.webp)
Parameters
List of parameters
1-766
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the commissioning steps that have been carried out.
Note:
When motor rating plate parameters are changed, the final display is reset. When setting the individual bits, all of
the most significant bits are reset.
Bit 00 = Automatic parameterization (p0340 = 1, p3900 > 0).
Bit 02 = Motor data identification (p1910 = 1) successfully completed.
Bit 03 = Rotating measurement (p1960 = 1, 2) successfully completed.
Bit 04 = Motor encoder adjustment (p1990 = 1 of 1960 = 1) successfully completed.
Bit 15 = Equivalent circuit diagram parameters of the motor were subsequently manually changed.
Description:
Displays the commissioning steps that have been carried out.
r3925[0...n]
Identification final display / Ident final_disp
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Complete calculation of motor/control
parameters carried out
Yes
No
-
02
Motor data identification carried out at
standstill (p1910 = 1)
Yes
No
-
03
Rotating measurement carried out (p1960 =
1 or 2)
Yes
No
-
04
Motor encoder adjustment carried out
(p1990 = 1)
Yes
No
-
05
Motor encoder manually adjusted
Yes
No
-
15
Motor equivalent circuit diagram parameters
changed
Changed
Not changed
-
r3925[0...n]
Identification final display / Ident final_disp
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Complete calculation of motor/control
parameters carried out
Yes
No
-
02
Motor data identification carried out at
standstill (p1910 = 1)
Yes
No
-
03
Rotating measurement carried out (p1960 =
1 or 2)
Yes
No
-
04
Motor encoder adjustment carried out
(p1990 = 1)
Yes
No
-
10
Automatic parameterization only for V/f con-
trol (r0108.2 = 0)
Yes
No
-
15
Motor equivalent circuit diagram parameters
changed
Changed
Not changed
-