![Siemens SINAMICS S Series List Manual Download Page 927](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427927.webp)
List of parameters
Parameters
1-927
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p8500
Description:
Displays the signals of the bitwise received data.
These signals were interconnected and transferred to another Control Unit via BI: p8501[0...15].
Dependency:
Refer to: p8501
Description:
Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred to another Control Unit via CI: p8502.
Dependency:
Refer to: p8502
Description:
Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred to another Control Unit via CI: p8503.
Dependency:
Refer to: p8503
r8511.0...15
BO: Data transfer 1 receive bitwise / Trans 1 recv bit
CU_CX32, CU_LINK
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Receive signal from BI: p8501
On
Off
-
01
Receive signal from BI: p8501
On
Off
-
02
Receive signal from BI: p8501
On
Off
-
03
Receive signal from BI: p8501
On
Off
-
04
Receive signal from BI: p8501
On
Off
-
05
Receive signal from BI: p8501
On
Off
-
06
Receive signal from BI: p8501
On
Off
-
07
Receive signal from BI: p8501
On
Off
-
08
Receive signal from BI: p8501
On
Off
-
09
Receive signal from BI: p8501
On
Off
-
10
Receive signal from BI: p8501
On
Off
-
11
Receive signal from BI: p8501
On
Off
-
12
Receive signal from BI: p8501
On
Off
-
13
Receive signal from BI: p8501
On
Off
-
14
Receive signal from BI: p8501
On
Off
-
15
Receive signal from BI: p8501
On
Off
-
r8512
CO: Data transfer 0 receive wordwise / Trans 0 recv word
CU_CX32, CU_LINK
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2211
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r8513
CO: Data transfer 1 receive wordwise / Trans 1 recv word
CU_CX32, CU_LINK
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2211
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-