Parameters
List of parameters
1-66
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the actual velocity setpoint after the setpoint filters.
Description:
Displays the actual, smoothed actual speed for speed control.
Dependency:
Refer to: r0021
Note:
The speed actual value is calculated in sensorless operation. For operation with encoder, r0063 is smoothed with
p1441.
The speed actual value is available smoothed (r0021) and unsmoothed (r0063).
Description:
Displays the actual, smoothed velocity actual value for velocity control.
Dependency:
Refer to: r0021
Note:
The velocity actual value is calculated in sensorless operation. For operation with encoder, r0063 is smoothed with
p1441.
The velocity actual value is available smoothed (r0021) and unsmoothed (r0063).
Description:
Displays the currently smoothed speed actual value.
Note:
For Terminal Module 41 (TM41), this value is used to interconnect with standard telegram 3 and is always zero.
r0062
CO: Velocity setpoint after the filter / v_set after filter
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1590, 1750,
5020, 5030, 5210, 6030
P-Group:
Displays, signals
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
r0063
CO: Speed actual value after actual value smoothing / n_ist smooth
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1580, 1590,
4710, 5300
P-Group:
Displays, signals
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r0063
CO: Actual velocity smoothed / v_act smooth
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1580, 1590,
4710, 5300
P-Group:
Displays, signals
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
r0063
CO: Speed actual value after actual value smoothing / n_ist smooth
TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]