Parameters
Parameters for data sets
1-1080
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
p2204[0...n]
CO: Technology controller, fixed value 4 / Tec_ctrl fix val 4
p2205[0...n]
CO: Technology controller, fixed value 5 / Tec_ctrl fix val 5
p2206[0...n]
CO: Technology controller, fixed value 6 / Tec_ctrl fix val 6
p2207[0...n]
CO: Technology controller, fixed value 7 / Tec_ctrl fix val 7
p2208[0...n]
CO: Technology controller, fixed value 8 / Tec_ctrl fix val 8
p2209[0...n]
CO: Technology controller, fixed value 9 / Tec_ctrl fix val 9
p2210[0...n]
CO: Technology controller, fixed value 10 / Tec_ctrl fix val10
p2211[0...n]
CO: Technology controller, fixed value 11 / Tec_ctrl fix val11
p2212[0...n]
CO: Technology controller, fixed value 12 / Tec_ctrl fix val12
p2213[0...n]
CO: Technology controller, fixed value 13 / Tec_ctrl fix val13
p2214[0...n]
CO: Technology controller, fixed value 14 / Tec_ctrl fix val14
p2215[0...n]
CO: Technology controller, fixed value 15 / Tec_ctrl fix val15
p2230[0...n]
Technology controller motorized potentiometer configuration / Tec_ctr mop config
p2237[0...n]
Technology controller motorized potentiometer maximum value / Tec_ctrl mop max
p2238[0...n]
Technology controller motorized potentiometer minimum value / Tec_ctrl mop min
p2240[0...n]
Technology controller motorized potentiometer starting value / Tec_ctrl mop start
p2247[0...n]
Technology controller motorized potentiometer ramp-up time / Tec_ctr mop t_r-up
p2248[0...n]
Technology controller motorized potentiometer ramp-down time / Tec_ctrMop t_rdown
p2502[0...n]
LR encoder assignment / Encoder assignment
p2503[0...n]
LR length unit LU per 10 mm / LU per 10 mm
p2504[0...n]
LR motor/load motor revolutions / Mot/load motor rev
p2505[0...n]
LR motor/load motor revolutions / Mot/load motor rev
p2506[0...n]
LR length unit LU per load revolution / LU per load rev
p2519[0...n]
LR position actual value preprocessing config. DDS changeover / s_act config DDS
p2533[0...n]
LR position setpoint filter, time constant / s_set_filt T
p2534[0...n]
LR speed pre-control factor / n_prectrl fact
p2535[0...n]
LR speed pre-control balancing filter dead time / n_prectrFlt t_dead
p2536[0...n]
LR speed pre-control, symmetrizing filter PT1 / n_prectrl filt PT1
p2538[0...n]
LR proportional gain / Kp
p2539[0...n]
LR integral time / Tn
p2546[0...n]
LR dynamic following error monitoring tolerance / s_delta_monit tol
p2567[0...n]
LR torque pre-control moment of inertia / M_prectr M_inertia
p2567[0...n]
LR force pre-control mass / F_prectrl mass
p2634[0...n]
EPOS fixed stop maximum following error / Following err max
p2720[0...n]
Load gearbox configuration / Load grbx config
p2721[0...n]
Load gearbox, rotary absolute gearbox, revolutions, virtual / Abs rot rev
p2722[0...n]
Load gearbox, position tracking tolerance window / Pos track tol
r2723[0...n]
CO: Load gearbox absolute value / Load grbx abs_val
r2724[0...n]
CO: Load gearbox position difference / Load grbx pos diff
p2900[0...n]
CO: Fixed value 1 [%] / Fixed value 1 [%]
p2901[0...n]
CO: Fixed value 2 [%] / Fixed value 2 [%]
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
p2930[0...n]
CO: Fixed value F [N] / Fixed value F [N]
p3201[0...n]
Excitation current outside the tolerance threshold value / I_exc n.Tol thresh
p3202[0...n]
Excitation current outside the tolerance hysteresis / I_exc n.Tol hyst
p3203[0...n]
Excitation current outside the tolerance delay time / I_exc n.Tol t_del
p3204[0...n]
Flux outside the tolerance threshold value / Flux n. tol thresh
p3205[0...n]
Flux outside the tolerance hysteresis / Flux n. tol hyst
p3206[0...n]
Flux outside tolerance delay time / Flux n. tol t_del
p3207[0...n]
Zero current signal threshold value / I_0_sig thresh
p3208[0...n]
Zero current signal hysteresis / I_0_sig hyst
p3209[0...n]
Zero current signal delay time / I_0_sig t_del
p3704[0...n]
APC filter activation / APC filter act