List of parameters
Parameters
1-801
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the normalization characteristic for the analog input of terminal module 41 (TM41).
The normalization characteristic for the analog inputs is defined using two points.
This parameter specifies the y coordinate (percentage) of the 2nd value pair of the characteristic.
Index:
[0] = AI 0 (X523.1/X523.2)
Note:
The parameters for the characteristic do not limit.
Description:
Sets the response threshold for wire-breakage monitoring of the analog inputs of terminal module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The wire breakage monitoring is active for the following type of analog input: p4056[x] = 3 (current input unipolar,
monitored 4 mA ... 20 mA).
Refer to: r4056, p4056
Description:
Sets the delay time for wire-breakage monitoring of the analog inputs on terminal module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description:
Sets the offset for the analog inputs of Terminal Board 30 (TB30).
The offset is added to the input signal before the normalization characteristic.
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
p4060[0...0]
TM41 analog input, characteristic value y2 / TM41 AI char y2
TM41
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9663
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-1000.00 [%]
1000.00 [%]
100.00 [%]
p4061[0...1]
TM31 analog inputs, wire breakage monitoring response threshold /
TM31 WireBrkThresh
TM31
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9566, 9568
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [mA]
20.00 [mA]
2.00 [mA]
p4062[0...1]
TM31 analog inputs, wire breakage monitoring delay time / TM31 wirebrk t_del
TM31
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
9566, 9568
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
1000 [ms]
100 [ms]
p4063[0...1]
TB30 analog inputs offset / TB30 AI offset
TB30
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9104
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-20.000 [V]
20.000 [V]
0.000 [V]