List of parameters
Parameters
1-471
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the direct-axis voltage setpoint Ud.
Description:
Displays the quadrature-axis component of voltage setpoint Uq.
Description:
Defines the gain of the controller for resonance damping for operation with sensorless vector control in the range
that current is impressed.
Description:
Sets the speed threshold value to detect a stalled motor.
If the adaptation controller output exceeds the parameterized speed difference, then bit 11 in status word p1408 is
set.
Dependency:
If a stalled drive is detected (p1408.11 set), fault 7902 is output after the delay time in p2178.
Refer to: p2178
Note:
Speed monitoring is only effective in operation with a speed encoder (refer to p1300).
r1732
CO: Direct-axis voltage setpoint / Direct V set
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1630, 5714,
6714, 5718
P-Group:
Closed-loop control
Units group:
5_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
r1733
CO: Quadrature-axis voltage setpoint / Quad V set
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1630, 5714,
5718, 6714, 6719
P-Group:
Closed-loop control
Units group:
5_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
p1740[0...n]
Gain resonance damping for sensorless closed loop control / Gain res_damp
VECTOR (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL, FEM
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.025
p1744[0...n]
Motor model speed threshold stall detection / MotMod n_thr stall
VECTOR (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL, FEM
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
210000.00 [RPM]
100.00 [RPM]