![Siemens SINAMICS S Series List Manual Download Page 1437](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271437.webp)
List of faults and alarms
Faults and Alarms
3-1437
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
F01011 (N)
Download interrupted
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The project download was interrupted.
- the user prematurely interrupted the project download.
- the communication cable was interrupted (cable breakage, cable withdrawn).
Note:
The response to an interrupted download is the state "first commissioning".
Remedy:
- check the communication cable.
- download the project again.
- boot from previously saved files (power-down/power-up or p0976).
Reaction upon N:
NONE
Acknowl. upon N:
NONE
F01012 (N)
Project conversion error
Drive object:
SERVO, VECTOR
Reaction:
OFF2 (NONE)
Acknowledge:
IMMEDIATELY
Cause:
When converting the project of an older FW version, a fatal error occurred.
The fault value (r0949) specifies the number of the parameter that caused the error.
Notice:
For fault value 600, the motor temperature monitoring is no longer guaranteed.
Remedy:
The parameter specified in fault value (r0949) must be checked.
Notice: For fault value 600 the parameterization of p0600 (motor temperature sensor for monitoring) must be cor-
rected (refer to the function diagram 8016 and parameter description for p0600).
Reaction upon N:
NONE
Acknowl. upon N:
NONE
F01015
Internal software error
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
An internal software error has occurred.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry out a POWER ON (power off/on) for all components.
- upgrade the firmware release.
- contact the Hotline.
A01016 (F)
CompactFlash card changed
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
On the CompactFlash card, at least one file in the directory /SIEMENS/SINAMICS/ has been illegally changed with
respect to that supplied from the factory. No changes are permitted in this directory.
Alarm value (r2124, interpret decimal):
0: Checksum of one file is incorrect.
1: File missing.
2: Too many files.
3: Incorrect firmware version.
4: Incorrect checksum of the back-up file.
See also: r9925 (CompactFlash card file error)