Parameters
List of parameters
1-162
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the x coordinate (magnetizing current) for the 2nd value pair of the characteristic.
Sets the second magnetizing current of the saturation characteristic as a [%] referred to the rated magnetizing cur-
rent (r0331), for separately-excited synchronous motors referred to the no-load excitation current.
Dependency:
The following applies for the magnetizing currents:
p0366 < p0367 < p0368 < p0369
Refer to: p0363
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the x coordinate (magnetizing current) for the 3rd value pair of the characteristic.
Sets the third magnetizing current of the saturation characteristic as a [%] referred to the rated magnetizing current
(r0331), for separately-excited synchronous motors referred to the no-load excitation current.
Dependency:
The following applies for the magnetizing currents:
p0366 < p0367 < p0368 < p0369
Refer to: p0364
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the x coordinate (magnetizing current) for the 4th value pair of the characteristic.
Sets the fourth magnetizing current of the saturation characteristic as a [%] referred to the rated magnetizing cur-
rent (r0331), for separately-excited synchronous motors referred to the no-load excitation current.
Dependency:
The following applies for the magnetizing currents:
p0366 < p0367 < p0368 < p0369
Refer to: p0365
p0367[0...n]
Saturation characteristic I_mag 2 / Mot sat. I_mag 2
VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
PEM
Expert list:
1
Min Max
Factory
setting
5.0 [%]
800.0 [%]
75.0 [%]
p0368[0...n]
Saturation characteristic I_mag 3 / Mot sat. I_mag 3
VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
PEM
Expert list:
1
Min Max
Factory
setting
5.0 [%]
800.0 [%]
150.0 [%]
p0369[0...n]
Saturation characteristic I_mag 4 / Mot sat. I_mag 4
VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
PEM
Expert list:
1
Min Max
Factory
setting
5.0 [%]
800.0 [%]
210.0 [%]