![Siemens SINAMICS S Series List Manual Download Page 544](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427544.webp)
Parameters
List of parameters
1-544
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index 3: Device type
Index 4: Firmware version.
Index 5: Firmware date (year).
Index 6: Firmware date (day/month).
Description:
Connector output to interconnect PZD (setpoints) with double word format received from the PROFIBUS master.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 +10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
Dependency:
Refer to: r2050
Note:
IF1: Interface 1
Description:
Connector output to interconnect PZD (setpoints) with double word format received from the PROFIBUS master.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 +10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
[15] = PZD 16 + 17
[16] = PZD 17 + 18
[17] = PZD 18 + 19
r2060[0...14]
CO: IF1 PROFIdrive PZD receive double word / IF1 PZD recv DW
SERVO, TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
2440, 2460
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2060[0...30]
CO: IF1 PROFIdrive PZD receive double word / IF1 PZD recv DW
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
2440, 2460
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-