List of parameters
Parameters
1-879
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values:
0:
Connection at connector output r4818
1:
Connection at current setpoint after filter and r4818
2:
Connection as disturbing torque and r4818
3:
Connection at speed setpoint after filter and r4818
4:
Connection at current setpoint before filter and r4818
5:
Connection at speed setpoint before filter and r4818
99:
Connection at physical address and r4818
Description:
Sets the physical address where the function generator is to be connected.
Dependency:
Only effective when p4810 = 99.
Description:
Sets the reference value for 100 % for referred inputs.
Dependency:
Only effective when p4810 = 99.
Description:
Selects the required drive where the function generator is to be connected.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Dependency:
Only effective when p4810 = 1, 2, 3, 4 or 5.
Note:
For the function generator, only type SERVO drives can be used.
Description:
Displays the output signal for the function generator.
Dependency:
Refer to: p4810
Note:
The value is displayed independently of the function generator mode.
The signal is available as connector output for an ongoing interconnection.
p4812
Function generator physical address / FG phys address
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 4294967295
0
p4813
Function generator physical address reference value / FG phys addr ref
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1.00 1000000.00
1.00
p4815[0...2]
Function generator drive number / FG drive number
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
r4818
CO: Function generator output signal / FG output signal
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]