![Siemens SINAMICS S Series List Manual Download Page 841](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427841.webp)
List of parameters
Parameters
1-841
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Is used to synchronize the timer of terminal module 17 (TM17) with the system time of the DP master.
Bit 12 ... 15:
After synchronization with the DP master, the module sends its sign-of-life in the form of a counter.
Bit 0:
This SYNC signal is set if the module has aligned its time to the system time of the DP master.
Bit 9:
This bit is set if a fault has occurred on the module (r0945).
Description:
Is used to synchronize the timer of terminal module 15 (TM15) with the system time of the DP master.
Bit 12 ... 15:
After synchronization with the DP master, the module sends its sign-of-life in the form of a counter.
Bit 0:
This SYNC signal is set if the module has aligned its time to the system time of the DP master.
Bit 9:
This bit is set if a fault has occurred on the module (r0945).
Description:
Displays status for digital input 0 ... 15 of terminal module 17 (TM17).
r4301
TM17 module synchronization / TM17 Module sync
TM17
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4301
TM15 module synchronization / TM15 module sync
TM15
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4304
TM17 status, digital input 0 ... 15 / TM17 St DI 0-15
TM17
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI/DO 0 (X520.2)
On
Off
-
01
DI/DO 1 (X520.3)
On
Off
-
02
DI/DO 2 (X520.5)
On
Off
-
03
DI/DO 3 (X520.6)
On
Off
-
04
DI/DO 4 (X520.8)
On
Off
-
05
DI/DO 5 (X520.9)
On
Off
-
06
DI/DO 6 (X521.2)
On
Off
-
07
DI/DO 7 (X521.3)
On
Off
-
08
DI/DO 8 (X521.8)
On
Off
-
09
DI/DO 9 (X521.9)
On
Off
-
10
DI/DO 10 (X522.2)
On
Off
-
11
DI/DO 11 (X522.3)
On
Off
-
12
DI/DO 12 (X522.5)
On
Off
-