Parameters
List of parameters
1-322
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the ramp-down time from the maximum speed down to zero speed for the OFF3 command.
Note:
This time can be exceeded if the DC-link voltage reaches its maximum value.
Description:
Sets the initial rounding-off time for OFF3 for the extended ramp generator.
Description:
Sets the final rounding-off time for OFF3 for the extended ramp generator.
Description:
Sets the signal source for control word 1 bit 4 (operating condition/disable ramp-function generator).
Dependency:
Refer to: p1141, p1142
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Bit 4 = 0: Inhibits the ramp-function generator (the ramp-function generator output is set to zero)
Bit 4 = 1: Operating condition (the ramp-function generator can be enabled)
Description:
Sets the signal source for control word 1 bit 4 (operating condition/disable ramp-function generator).
p1135[0...n]
OFF3 ramp-down time / RFG OFF3 t_ramp-dn
VECTOR
Can be changed:
C2(1), U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3060, 3070
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
600.000 [s]
3.000 [s]
p1136[0...n]
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3070, 3080
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
30.000 [s]
0.000 [s]
p1137[0...n]
OFF3 final rounding-off time / RFG OFF3 t_end_del
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3070
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
30.000 [s]
0.000 [s]
p1140[0...n]
BI: Enables the ramp-function generator / Enable RFG
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2442, 2443,
2501
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p1140
BI: Enables the ramp-function generator / Enable RFG
TM41
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1