List of parameters
Parameters
1-1037
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
SI: Safety Integrated
SMM: Safe Motion Monitoring
STO: Safe Torque Off / SH: Safe standstill
Description:
Sets the enable signal for the "Safe Brake Control" function (SBC) on the Motor Module.
0: Inhibit SBC
1: Enable SBC
Dependency:
Refer to: p9602
Note:
The "Safe Brake Control" function is not activated until at least one safety monitoring function has been enabled
(i.e. p9501 not equal to 0 and/or p9801 not equal to 0).
The parameterization "no motor holding brake available" and "Safe Brake Control" enabled (p1215 = 0, p9602 =
p9802 = 1) is not practical if there is no motor holding brake.
The parameterization "motor holding brake the same as sequence control, connection via BICO" and "Safe Brake
Control" enabled (p1215 = 3, p9602 = 1, p9802 = 1) is not practical.
It is not permissible to parameterize "motor holding brake without feedback signals" and also enable "safe brake
control" (p1278 = 1, p9602 = 1, p9802 = 1).
MM: Motor Module
SBC: Safe Brake Control
SI: Safety Integrated
Description:
Sets the PROFIsafe address of the Motor Module.
Description:
Sets the tolerance time to change over the safety-related inputs (SGE) on the Motor Module.
An SGE changeover is not simultaneously effective due to the different runtimes in the two monitoring channels.
After an SGE changeover, dynamic data is not subject to a data cross-check during this tolerance time.
Dependency:
Refer to: p9650
Note:
For a data cross-check between p9650 and p9850, a difference of one Safety monitoring clock cycle is tolerated.
The parameterized time is internally rounded-off to an integer multiple of the monitoring clock cycle.
SGE: Safety-related input (e.g. STO terminals)
p9802
SI enable Safe Brake Control (Motor Module) / SI enable SBC MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
2814
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p9810
SI PROFIsafe address (Motor Module) / SI PROFIsafe MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFE hex
0000 hex
p9850
SI SGE changeover tolerance time (Motor Module) / SI SGE_chg tol MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2810
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [µs]
2000000.00 [µs]
500000.00 [µs]