![Siemens SINAMICS S Series List Manual Download Page 261](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427261.webp)
List of parameters
Parameters
1-261
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Re bit 0, 1, 2, 4, 5, 6, 9:
For PROFIdrive, these signals are used for status word 1.
Re bit 13:
When the "Safe Brake Control" (SBC) is activated and selected, the brake is no longer controlled using this signal.
Re bit 14, 15:
These signals are only of significance when the "extended brake control" function module is activated (r0108.14 =
1).
Description:
Displays the status word of the sequence control.
Note:
Re bit 0, 1, 2, 6:
For PROFIdrive, these signals are used for status word 1.
r0899.0...15
CO/BO: Status word sequence control / ZSW seq_ctrl
TM41
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
9680
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready to power up
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
04
Coast down active
No
Yes
-
05
Quick Stop active
No
Yes
-
06
Power-on inhibit
Yes
No
-
09
Control requested
Yes
No
-
13
Zero mark enabled
Yes
No
-
14
Track A/B enabled
Yes
No
-
15
Interface encoder emulation enabled
Yes
No
-