![Siemens SINAMICS S Series List Manual Download Page 504](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427504.webp)
Parameters
List of parameters
1-504
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[10] = Force constant identification current
[11] = Force characteristic identification current measuring point 1
[12] = Force characteristic identification current measuring point 2
[13] = Force characteristic identification current measuring point 3
[14] = Force characteristic identification current measuring point 4
[15] = Force characteristic identification current measuring point 5
[16] = Force characteristic identification current measuring point 6
[17] = Force characteristic identification current measuring point 7
[18] = Force characteristic identification current measuring point 8
[19] = Force characteristic identification current measuring point 9
[20] = Force characteristic identification current measuring point 10
Dependency:
Refer to: p1909, p1910, r1934, p1959, p1960
Note:
- the Lq characteristic consists of the value pairs from r1934 and r1935 with the same index.
- the force constant is identified with the current r1935[10] and displayed in r1937[0]. If the reluctance force constant
is identified (p1959.7 = 1), the force constant is identified with 150% rated current (p0305), otherwise with 100%
rated current.
- the force characteristic (r1937[1...10]) is identified in the range between the rated current (p0305) and the maxi-
mum current (p0640) (r1935[11...20]).
Description:
Displays the identification current to identify the q inductance ([0...9]).
Dependency:
Refer to: r1934, p1959, p1960
Note:
The Lq characteristic consists of the value pairs from r1934 and r1935 with the same index.
Description:
Displays the identified magnetizing inductance(gamma equivalent circuit diagram).
Dependency:
Refer to: p1909, p1910, r1913, r1915, r1927, p1959, p1960, r1962, r1963
Note:
This value corresponds to the value of the transformed magnetizing inductance (r0382).
Description:
Displays the identified torque constant/torque characteristic over the q current.
Index:
[0] = Torque constant identified
[1] = Torque characteristic identified measuring point 1
[2] = Torque characteristic identified measuring point 2
[3] = Torque characteristic identified measuring point 3
[4] = Torque characteristic identified measuring point 4
[5] = Torque characteristic identified measuring point 5
r1935[0...9]
q inductance identification current / Lq I_ident
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r1936
Magnetizing inductance identified / L_H ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r1937[0...10]
Torque constant identified / kT ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
28_1
Unit selection:
p0100
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Nm/A]
- [Nm/A]
- [Nm/A]