Parameters
List of parameters
1-646
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the modulo range for axes with modulo correction.
Dependency:
Refer to: p2577
Description:
Sets the signal source to activate modulo correction.
Dependency:
Refer to: p2576
Note:
When the signal state changes at the binector input, this only becomes effective in the "ready to power-up" state.
Selecting modulo correction:
The actual position setpoint in the modulo range is corrected. The position actual value differs from the position set-
point by the following error and can also leave the modulo range.
De-selecting modulo correction:
It is based on the actual position actual value.
Description:
Sets the signal source for the software limit switch minus.
Dependency:
Refer to: p2579, p2580, p2581, p2582
Refer to: A07469, A07477, A07479, F07481
Notice:
A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note:
The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description:
Sets the signal source for the software limit switch plus.
p2576
EPOS modulo correction, modulo range / Modulo corr range
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
3635
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 [LU]
2147482647 [LU]
360000 [LU]
p2577
BI: EPOS modulo correction activation / Modulo corr act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3630, 3635
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2578
CI: EPOS software limit switch minus signal source / SW limSw Min S_src
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2580[0]
p2579
CI: EPOS software limit switch plus signal source / SW limSwPlus S_src
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2581[0]