List of parameters
Parameters
1-555
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
[25] = PZD 26
[26] = PZD 27
[27] = PZD 28
[28] = PZD 29
[29] = PZD 30
[30] = PZD 31
[31] = PZD 32
Note:
IF1: Interface 1
Value range:
0 - 242: Byte offset
255: Not occupied
Description:
Displays the PZD byte offset in the PROFIdrive send telegram (master output).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
Note:
IF1: Interface 1
Value range:
0 - 242: Byte offset
255: Not occupied
Description:
Displays the addresses of the slaves (peers) where peer-to-peer data transfer has been configured via PROFIBUS.
r2076[0...4]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
TB30, TM15DI_DO,
TM31
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2077[0...15]
PROFIBUS diagnostics peer-to-peer data transfer addresses / PB diag peer addr
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-