List of parameters
Parameters
1-745
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the frequency difference between the measured target frequency and output frequency of the gating unit
of the closed-loop control for line-drive synchronization.
Description:
Sets the threshold value of the frequency difference to activate the closed-loop phase control for line-drive synchro-
nization.
The closed-loop phase control is activated (r3819.6 = 1), if the frequency difference is less that the threshold value.
Description:
Displays the phase difference between the measured target phase and phase of the gating unit of the closed-loop
control for line-drive synchronization.
Description:
Sets the phase setpoint for the line-drive synchronization.
Description:
Sets the frequency limiting of the phase controller output for the line-drive synchronization.
r3805
CO: Sync-line-drive frequency difference / Sync f_diff
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
7020
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
p3806[0...n]
Sync-line-drive frequency difference threshold value / Sync f_diff thresh
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7020
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Hz]
1.00 [Hz]
0.10 [Hz]
r3808
CO: Sync-line-drive phase difference / Sync phase diff
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
7020
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [°]
- [°]
- [°]
p3809[0...n]
Sync-line-drive phase setpoint / Sync phase setp
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7020
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-180.00 [°]
179.90 [°]
0.00 [°]
p3811[0...n]
Sync-line-drive frequency limiting / Sync f_lim
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7020
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Hz]
1.00 [Hz]
0.20 [Hz]