List of parameters
Parameters
1-905
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the actual value of the voltage measured at the 10 V input 2 of the Voltage Sensing Modules (VSM).
The average value of all VSM is displayed in r3674.
Dependency:
Refer to: p3670
Note:
10 V input 2: Terminals X520.3 and X520.4
Description:
Displays the capacitance of the line filter, phase U of the particular Voltage Sensing Module (VSM).
The average value of all VSM is displayed in r3677[0].
Dependency:
Refer to: p3676
Note:
Prerequisites:
The monitoring of the filter capacitance is activated.
Description:
Displays the capacitance of the line filter, phase V of the particular Voltage Sensing Module (VSM).
The average value of all VSM is displayed in r3677[1].
Dependency:
Refer to: p3676
Note:
Prerequisites:
The monitoring of the filter capacitance is activated.
Description:
Displays the capacitance of the line filter, phase W of the particular Voltage Sensing Module (VSM).
The average value of all VSM is displayed in r3677[2].
Dependency:
Refer to: p3676
Note:
Prerequisites:
The monitoring of the filter capacitance is activated.
r7316[0...n]
CO: Par_circuit VSM 10 V input 2 actual value / VSM inp 2 V_act
A_INF (Parallel),
S_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
p0140
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r7320[0...n]
Par_circuit VSM line filter capacitance phase U / VSM filt C phase U
A_INF (Parallel),
S_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
p0140
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [µF]
- [µF]
- [µF]
r7321[0...n]
Par_circuit VSM line filter capacitance phase V / VSM filt C phase V
A_INF (Parallel),
S_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
p0140
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [µF]
- [µF]
- [µF]
r7322[0...n]
Par_circuit VSM line filter capacitance phase W / VSM filt C phase W
A_INF (Parallel),
S_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
p0140
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [µF]
- [µF]
- [µF]