List of parameters
Parameters
1-173
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
The lowest permissible value is 250 nm.
Description:
Sets the number of pulses for a rotary encoder.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
The number of pole pairs for a resolver is entered here.
The smallest permissible value is 1 pulse.
Description:
Sets the number of pulses for a rotary encoder.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description:
Setting to invert actual values.
Note:
The inversion influences the following parameters:
Bit 00: r0061, r0063 (exception: sensorless control), r0094
Bit 01: r0482, r0483
p0408[0...n]
Rotary encoder pulse No. / Rot enc pulse No.
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
EDS, p0140
Func. diagram:
4010, 4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 16777215
2048
p0408
Rotary encoder pulse No. / Rot enc pulse No.
TM41
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
9674, 9676
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1000 8192
2048
p0410[0...n]
Encoder inversion actual value / Enc inv act value
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Invert speed actual value
Yes
No
4710,
4715
01
Invert position actual value
Yes
No
4704