Parameters
List of parameters
1-178
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the minimum delay time between two data transfers of the absolute value for an SSI encoder.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description:
Sets the configuration for an SSI encoder.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
Re bit 06:
The quiescent signal level of the data line corresponds to the inverted, set level.
Description:
Sets the configuration of the Sensor Module.
p0428[0...n]
Encoder SSI monoflop time / Enc SSI t_monoflop
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [µs]
65535 [µs]
30 [µs]
p0429[0...n]
Encoder SSI configuration / Enc SSI config
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Transfer code
Binary code
Gray code
-
02
Transfer absolute value twice
Yes
No
-
06
Data line during the monoflop time
High level
Low level
-
p0430[0...n]
Sensor Module configuration / SM config
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-
-
1110 0000 0000 1000 0000
0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
17
Burst oversampling
Yes
No
-
19
Safety position actual value sensing
Yes
No
-
20
Speed calculation mode (only SMC30)
Incremental diff
Flank time meas
-
21
Zero mark tol
Yes
No
-
22
Rot pos adapt
Yes
No
-
27
Extrapolation of the SSI position value
Yes
No
-
29
Phase correction
Yes
No
-
30
Amplitude correction
Yes
No
-
31
Offset correction
Yes
No
-